0L6770 LEAK DETECTION EQUIPMENT
ULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak Detector w/ Vac Pump Ref: 392205

ULTRATEST, LEYBOLD-HERAEUS, No. M2, M2DS, M2BY, Helium Leak Detector w/ Vac Pump
           
           

          To the best of our knowledge all details listed below are deemed correct. 
          It is the buyer's responsibility to confirmed prior to purchase.
          
          
          Equipped with:
             Leybold-Heraeus NT 150/360 Frequency Converter (see below for details)
             Leybold-Heraeus, #WAU500/D90A, Verti Pump System
                   Root Pump WAU500 s/n 1185330234
                            Approved Fluid HE-200
                   Vane Pump D90A s/n 1285252787
                            Approved Fluid HE-175
                    Voltage: 460V / 3 / 60
                    Starting Amp:                45 Amp
                    Running Current:              9 Amp
          
          Unit appears to be in Excellent condition with very little use; includings
          
          many fixtures
          
          
          GENERAL SPECIFICATIONS FOR MACHINE AS FOLLOWS:
          
          Smallest Detectable Leak
             w/Options Quick-Test:           10-6 atm cc/sec
             w/out Quick-Test:               2x10 -10 atm cc/sec
             w/out Quick-Test w/reduced
               Pumping Speed:                2x10 -11 atm cc/sec
          Full Scale Leak-Rate Meter Reading
             w/out Quick-Test:               10x10 -9 to 10x10 -6 atm cc/sec
             w/Quick-Test:                   Must multiply meter reading by correction
                                               factor (see manual Section 4-3-2)
          Maximum Safe Operating Pressure
             In the Mass Spectrometer (PIII) 1x10 -4 mbar
          Detectable Masses:                 3 and helium 4
          Adjustable Emission Current:       0.6 to 5mA
          Total Pressure Reading
             Thermovac (PII):                10 -3 to 1000 mbar
             Ionization Gauge (PIII):        10 -6 to 10 -3 mbar
          Maximum Gas Flow
             @ Test Port:                    2x10 -3 atm cc/sec
          Pumping Speet @ Test Port and In Mass Spectrometer
             Ultratest M2:                   For Helium 20 ltr/sec
                                             For Air 7.5 ltr/sec
             Ultratest M2DS/M2BYTC/M2BYPC:   For Helium 16 ltr/sec
                                             For Air 6 ltr/sec
          Backing Pump:                      Trivac Vane Pump
             M2 and M2DS:                    D2A (2.2cfm or 1.1 ltr/sec displacement)
             M2BYTC/M2BYPC:                  D4A (4.5cfm or 2.1 ltr/sec displacement)
             Pump Vluis for Trivac:          HE-200
          Diffusion Pump:                    Leybodiff 180L
             Pumping Speed For Air:          180 ltr/sec (381cfm) at 10 -5 mbar;
                                               throtted to approx. 2 ltr/sec
             Pump Fluid For Diff. Pump:      HE-300 (50cc optimum)
          Cold Trap
             Capacity:                       2.4 qts of liquid nitrogen (LN2)
             Holding Time:                   Approx 20 hrs w/one Filling
          Outputs - Recorder Socket But
             Pin 5 (+) to Pin 3:             0 - 10 VDC (10 VDC is full scale
                                              deflectio of leak-rate meter)
             Pin 1 (+) to Pin 3:             1 - 7 VDC in 1 volt steps corresponding
                                               to the 7 leak-rate positions on the
                                               range switch.  The output is 0 when the
                                               range switch is not in a leak-rate
                                               position.
             Triggers 1 & 2 (Optional):      6 Amp, 220 VAC max.
          Mains Supply:                      115V, 60 Hz
          Recommended Mains Fuse:            10 Amp
          Dimensions
             PK Unit:                        22.8" x 16.3" x 16.5"
             Electronic Control Cabinet:     9.2" x 10.3" x 16.1"
             FB Remote Control Module:       8.7" x 9.1" x 5.1"
             Optional Quick-Test Housing:    8.4" x 6" x 3.2"
          Weights
             PK Unit:
               Ultratest M2:                 154 lbs
               Ultratest M2DS:               165 lbs
               Ultratest M2BYTC/M2BYPC:      176 lbs
             Electrical Control Cabinet:     28.7 lbs
             FB Remote Control Module:       4.4 lbs
             Optional Quick-Test Housing:    5.5 lbs
          Data for Optional Quick-Test
             Smallest Detectable Leakrate:   10 -6 atm cc/sec
             Gas Throughput in Probe:        Approx 90 atm cc/minute
             Sampled Gas Inlet to Leak 
               Detector:                     Approx 10 - 3 atm cc/sec
             Connecting Flange:              NW40KF
             Connecting Flange for 
               Calibrated Leak:              NW10KF
             Line Voltage:                   60 Hz, 220 V
             Dimensions of Housing:          8.4" x 6" x 3.2"
             Weight of Housing:              5.5 lbs
             Probe PVC Tubing
               Length:                       15' standard, up to 100' optional
             Response time for 15' tubing:   Less than 2 seconds
             Weight:                         1.1 lbs
          
          GENERAL SPECIFICATIONS FOR FREQUENCY CONVERTER AS FOLLOWS:
          Power Source
             Voltage:                        Single phase, 100/120/220/240
             Frequency:                      47-63 Hz
          (Currently set up for 120V / 60Hz)
             Steady Rate Max:                680 VA
             Transient (<0.5 Sec):           750 VA
          Output Values
             Voltage:                        45 Vrms
             Rated Frequency:
               TMP-150:                      840 Hz
               TMP-360:                      760 Hz
             Max. Power:
               Acceleration:                 380 Watts
               TMP-150 Normal Operation:     112 Watts
               TMP-360 Normal Operation:     260 Watts
             Relay Contacts:
               Maximum:                      24 VDC & 240 VAC @ 8 A
               Mininum:                      5 VDC @ 1 mA
          Environment
             Operating Temperature Range:    0 deg to 45 deg C
             Storage Temperature Range:      -40 deg to +85 deg C
          Mechanical Design
             Dimensions approx (w x h x d):  8.39" x 5.08" x 11.42"
             Weight approx:                  18.7 lbs
          
          Ultratest Module MS:  16 1/2" x 9 1/4" x 11" 180 lbs
          Ultratest PK Module:  29" x 29" x 26 1/2" 180 lbs
          Quick Test Module: 7" x 6" x 8 1/2" 10 lbs
          Cart For Machine: 43" x 25 1/2" x 34 3/4"  250 lbs
          Wooden Box of Parts:  56 1/2" x 56 1/2" x 24 1/2" 250 lbs
          Pumping System:  30" x 49" x 57" 3,500 lbs
          
          
          

Automatics & Machinery Co Inc
150 Martin St Longmont CO 80501-5939
Tel: 800-543-7666 Fax: 303-651-6556
Email (Request Quote): steve@automatics.com
Web: www.automatics.com



- Search equipment by:  
 


Used Equipment
Used Equipment
Used Equipment
Used Equipment
UEN is a product of and is operated by Halliburton Systems Inc of Denville NJ
Used Equipment
Used Equipment