0G2906 GENERATORS, A.C., STEAM TURBINE DR., CONDENS'G
58000 KW, ANSALDO 1000 PSIG, 13800 V, 3/60HZ, 1997; -1 Ref: 45562

STEAM TURBINE:
Manufacturer: ANSALDO
Model: SCSF
Rating: 58,000 Kw
Speed: 3600 RPM
Inlet Steam temp: 900 deg F (483C)
Inlet Steam Pressure: 1000 psig (69 Bar)
Stages: 16
Date of Manufacture: 1997

GENERATOR:
Manufacturer: ANSALDO (Italy)
Type: WY18Z-049LLT
Rating: 60,350 Kw
Speed: 3600 RPM
Current: 2970 A
Voltage: 13.8 kV, +/- 5%
Frequency: 60 Hz
Phases: 3
Power factor: 0.85
Year of Manufacture: 1998

SCOPE OF SUPPLY:
Lubrication System


HISTORY:

The steam turbine governor was replaced in 2013 by ABB. The generator
has 24,800 hours of operation since the last major maintenance, The steam
turbine has about 36,210 hours since the last major maintenance.



This equipment is currently installed. Asking price is negotiable depending
upon Buyer's preferred INCOTERMS: EXW, FOB, FAS, or DDP (directly to Buyer's
site with all costs included).
with all costs included).

Belyea Co Inc
2200 Northwood Ave Easton PA 18045-2239
Tel: 610-515-8775 Fax: 610-258-1230
Email (Request Quote): info@belyeapower.com